Filter Results By:

Products

Applications

Manufacturers

Showing results: 736 - 750 of 852 items found.

  • LXI Matrix Switching Unit

    ProDAQ 6140 - Bustec Ltd.

    The ProDAQ 6140 provides a relay matrix which can be fitted between the sensors and actuators on a device under test and the data acquisition and control system. It allows to separately connect/disconnect the signals from either side and to connect them to an internal bus. In this way signals can be routed via the bus to new destinations or the bus can be used to monitor or supply test signals. This allows calibrating and debugging the system without disconnecting and separating channels throughout the system wiring.

  • PXI 5A Fault Insertion Switch 5-Channel

    40-196-101 - Pickering Interfaces Ltd.

    The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.

  • PXI 5A Fault Insertion Switch 10-Channel

    40-196-001 - Pickering Interfaces Ltd.

    The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.

  • Digital Test Switch

    FT-14D - ABB Ltd.

    Test switch solution for digital switchgear using current and voltage sensors. With the FT-14D Digital FlexitestTM switches, a new era of protection relay testing can be performed more safely, quickly and easily. The FT-14D switch allows a customer to integrate current and voltage sensors within digital switchgear and protective relays and thereby enable the Industrial Internet of Things.

  • Power device test system

    ShibaSoku Co., Ltd.

    This system is suitable for DC testing of IGBT, IGBT module (1in1~7in1). Built-in hi-current switching relay circuit inside test head, it is capable ofDC testing from device itself to module. Highly accurate repeatability testing is available by high speed rise time which is suppressed its heat in hi-current

  • PXI/PXIe Microwave Multiplexer, Single SP4T, 6 GHz, 50 Ω, SMA, Failsafe

    42-784B-101 - Pickering Interfaces Ltd.

    The single slot remote multiplexer versions occupy less PXI panel space and allow the microwave relays to be placed closer to the UUT and other RF test equipment. In some applications it can shorten the length of RF cable runs and improve system performance. The remote multiplexers are supplied complete with a 1.5 m interface cable.

  • PXI/PXIe Microwave Multiplexer, Single SP6T, 6 GHz, 50 Ω, SMA, Failsafe

    42-784B-001 - Pickering Interfaces Ltd.

    The single slot remote multiplexer versions occupy less PXI panel space and allow the microwave relays to be placed closer to the UUT and other RF test equipment. In some applications it can shorten the length of RF cable runs and improve system performance. The remote multiplexers are supplied complete with a 1.5 m interface cable.

  • PXI - Test System

    TOPTEST GmbH

    We provide a complete PXI test system made by PXI individual components: 19'' rack, Measuring and stimuli cards, Relay cards, Power Supplies, Integration additional protocol cards such as CAN and CANopen, Boundary Scan, Integration of additional test hardware

  • RF Microwave Switching

    Keithley S46 - Tektronix, Inc.

    S46 and S46T Microwave Switch Systems are designed to simplify the automated switching needed to test a wide range of RF and telecommunication products and devices. The S46 can control 32 relay contacts in a package as small as a 2U high (3.5 in) full-rack enclosure. Choose the System 46T if your application requires a terminated configuration. It builds on the design technology of the unterminated System 46. The System 46T accommodates up to eight terminated SPDT coaxial microwave relays and four terminated multi-pole coaxial microwave relays.

  • PXIe-2737, 256-Crosspoint, 4x64, 2-Wire PXI Matrix Switch Module

    782835-37 - NI

    256-Crosspoint, 4x64, 2-Wire PXI Matrix Switch Module—The PXIe‑2737 is a high‐density 4x64 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.

  • PXIe-2738 , 256-Crosspoint, 8x32, 2-Wire PXI Matrix Switch Module

    782835-38 - NI

    256-Crosspoint, 8x32, 2-Wire PXI Matrix Switch Module—The PXIe‑2738 is a high‐density 8x32 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.

  • PXIe-2739 , 256-Crosspoint, 16x16, 2-Wire PXI Matrix Switch Module

    782835-39 - NI

    256-Crosspoint, 2-Wire PXI Matrix Switch Module—The PXIe‑2739 is a high‐density 16x16 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.

  • PXI-2576, 64‐Channel, 2-Wire, Multibank PXI Multiplexer Switch Module

    778572-76 - NI

    64‐Channel, 2-Wire, Multibank PXI Multiplexer Switch Module —The PXI‑2576 is a multibank PXI multiplexer switch module with 16 banks of 4x1 2‑wire multiplexers. With the flexible architecture of the PXI‐2576, you can configure it in a variety of topologies that make it suitable for parallel measurement operations requiring low‐channel counts, or you can combine all multiplexer banks to form a single high‐channel‐count multiplexer featuring 64 2‑wire channels. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.

  • PXI-2598, 26.5 GHz, 50 Ω, Dual-Transfer PXI Transfer Switch Module

    778572-98 - NI

    26.5 GHz, 50 Ω, Dual-Transfer PXI Transfer Switch Module—The PXI‑2598 is a general-purpose switch module for routing RF or microwave signals in automated test applications. You can use this module for basic signal routing or inserting and removing components in a signal path. The PXI‑2598 is also well suited for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. You can use its onboard relay count tracking to predict relay lifetime and reduce unexpected system downtime.

  • Primary Current Injection Sets

    R.R.Transformers & Equipments

    Protective devices such as relays, overload Coils, Circuit breakers and CTS etc. must be checked regularly to ensure that they are always ready to operate correctly, Routine current injection testing will quickly detect faulty or incorrectly adjusted protection circuits / devices & will be possible to prevent serious damage to the system. Primary injection kit is designed to operate on single phase 230/240 volts AC 50 HZ to develop smooth & continuous test current as for loading, calibrating, and testing of CTS, Bimetal Relays, Protection Relays etc. The test set gives high current output at low cost and with inherent safety. The primary current injection testing checks all parts of the protection system by injecting current down the cable / bus bars. The application of the primary current injection sets is to ascertain the current carrying capacity of any Conductor, insulator, connector or calibration of CTS / Bi-metallic relays etc.

Get Help